1.
|
Click on the button with the name of the project and select the Import Data (XML/ZIP) option to load the original basic tabs data into WebCDC.
|
2.
|
After the saved configuration has been imported navigate to the General tab, set the Delta generation field to Delta on CDC project.
|
3.
|
Next go to the Subscribers tab and add the new subscribers to the existing sites and also select the respective field in each new subscriber’s DELTA column.
|
4.
|
After adding the new subscriber entries, go back to the Start tab and ensure that the Delta generation field is set to Delta on CDC project.
|
5.
|
Click the OK button to begin the file generation and wait for the procedure to finish. A Progress Log window will provide the running status of the process. If any errors are encountered, then make any corrections needed and repeat the previous (Generate Config) step.
|
6.
|
When a window indicates ‘Finished with the generation of all the configuration files’, click its OK button to acknowledge that the generation of the configuration files is complete.
|
7.
|